Update server.js via upload script - 2026-08-31 14:42:55

This commit is contained in:
mike 2026-08-31 14:43:03 +08:00
parent 2e97832f98
commit f68261869d
1 changed files with 30 additions and 30 deletions

View File

@ -494,36 +494,36 @@ chargeCurrent充电电流、dimensions尺寸、netWeight净重
"outputPortCount": "迷你UPS专属这个型号有几路输出口数字字符串如 4不适用就填空字符串",
"outputPortTypes": "迷你UPS专属输出口类型数组只能用这些tokenUSB、DC、DC1、DC2、DC3、POE、Type-C、DC interface、POE interface不适用就填空数组",
"outputPorts": "迷你UPS专属数组每项 {\\"type\\":\\"USB\\",\\"voltage\\":\\"5Vdc\\",\\"current\\":\\"3.0A\\"}和outputPortTypes一一对应不适用就填空数组",
"inputVoltage": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS专属Input Voltage/输入电压(或Nominal Voltage/标称电压),如 110V/120Vac or 220V/230Vac不适用就填空字符串",
"inputVoltageRange": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS专属Voltage range/输入电压范围,如 162-268Vac/170-280Vac不适用就填空字符串",
"inputFrequency": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS专属Frequency/输入频率(范围),如 50/60HzAuto sensing或 40Hz~70Hz不适用就填空字符串",
"outputVoltage": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/太阳能混网逆变器专属Output Voltage/输出电压,如 110V/120Vac or 220V/230Vac不适用就填空字符串",
"outputVoltageRange": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS专属:输出电压范围(或Voltage Regulation/电压调整率),如 ±10% 或 ±1%;不适用就填空字符串",
"transferTime": "离线式UPS/在线互动式UPS专属Transfer time/转换时间,如 Typical 2-8ms, 13ms max机架式UPS这里填Inverter to Bypass那个转换时间AC to Battery那个用下面的transferTimeAcToBattery不适用就填空字符串",
"waveform": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS专属Wave form/波形,如 Simulated Sine Wave 或 pure sine wave不适用就填空字符串",
"inputVoltage": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Input Voltage/输入电压(或Nominal Voltage/标称电压),如 110V/120Vac or 220V/230Vac不适用就填空字符串",
"inputVoltageRange": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Voltage range/输入电压范围,如 162-268Vac/170-280Vac不适用就填空字符串",
"inputFrequency": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Frequency/输入频率(范围),如 50/60HzAuto sensing或 40Hz~70Hz不适用就填空字符串",
"outputVoltage": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS/太阳能混网逆变器专属Output Voltage/输出电压,如 110V/120Vac or 220V/230Vac不适用就填空字符串",
"outputVoltageRange": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属:输出电压范围(或Voltage Regulation/电压调整率),如 ±10% 或 ±1%;不适用就填空字符串",
"transferTime": "离线式UPS/在线互动式UPS专属Transfer time/转换时间,如 Typical 2-8ms, 13ms max机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS这里填Inverter to Bypass那个转换时间AC to Battery那个用下面的transferTimeAcToBattery不适用就填空字符串",
"waveform": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Wave form/波形,如 Simulated Sine Wave 或 pure sine wave不适用就填空字符串",
"batteryVoltage": "离线式UPS/在线互动式UPS/太阳能混网逆变器专属Battery Voltage/电池电压,如 12V 或 24V不适用就填空字符串",
"chargeCurrent": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS专属Charge current/充电电流,如 1A如果涉及【型号(L)拆分规则】,要按标准机型/长延时机型分别取Standard Model或Long-run Model那部分的数据不适用就填空字符串",
"frequencyRangeBatteryMode": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS专属Frequency range(battery mode)/频率范围(电池模式),如 50/60Hz±1Hz不适用就填空字符串",
"chargeTime": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS专属Charge time/充电时间(或Typical Recharge Time),如 8 hours recover to 90% capacity不适用就填空字符串",
"lcdDisplay": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS专属LCD display/LCD显示(或LCD Panel)能展示哪些信息,把原文整段抄下来,如 UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions不适用就填空字符串",
"chargeCurrent": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Charge current/充电电流,如 1A如果涉及【型号(L)拆分规则】,要按标准机型/长延时机型分别取Standard Model或Long-run Model那部分的数据不适用就填空字符串",
"frequencyRangeBatteryMode": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Frequency range(battery mode)/频率范围(电池模式),如 50/60Hz±1Hz不适用就填空字符串",
"chargeTime": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Charge time/充电时间(或Typical Recharge Time),如 8 hours recover to 90% capacity不适用就填空字符串",
"lcdDisplay": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属LCD display/LCD显示(或LCD Panel)能展示哪些信息,把原文整段抄下来,如 UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions不适用就填空字符串",
"ledDisplay": "离线式UPS/在线互动式UPS专属LED display/LED显示把各个模式对应的灯光颜色都列出来一行一条用\\n分隔如 AC mode: Green lighting\\nBattery mode: Yellow lighting\\nFault: Red lighting如果原文是中文且几个模式和颜色紧挨着写在一起、没有明显换行分隔比如\"市电模式 绿灯常亮 电池模式 黄灯常亮 故障 红灯常亮\"),要把每个模式和它后面紧跟着的颜色状态配对拆开,同样按一行一条的格式输出,如 市电模式:绿灯常亮\\n电池模式黄灯常亮\\n故障红灯常亮不适用就填空字符串",
"fullProtection": "离线式UPS/在线互动式UPS专属Full Protection/全面保护,如 Discharge, Short circuit and overload protection不适用就填空字符串",
"alarmInfo": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS专属Alarm/警告提示,把电池模式/低电量/过载/故障这几种蜂鸣提示规律都列出来(一行一条,用\\n分隔如 Battery mode: Sounding every 10 seconds\\nLow battery: Sounding every second\\nOverload: Sounding every 0.5 seconds\\nFault: Continuously sounding不适用就填空字符串",
"interfacePort": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS专属Interface/控制管理接口说明,如 USB/RS232 port(optional), Support windows xp/vista, windows 7/8/11 and MAC或 Smart RS-232/USB, Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC不适用就填空字符串",
"humidity": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/UPS配套锂电池系统/太阳能混网逆变器专属Humidity/湿度(或相对湿度),如 0-90% RH@0-40°C(Non-condensing) 或 5%~95%(无凝露);不适用就填空字符串",
"noiseLevel": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/太阳能混网逆变器专属Noise Level/噪音,如 Less than 40dB(1m spacing);不适用就填空字符串",
"phase": "机架式UPS/在线式高频UPS专属Phase/相数,如 1-phase input/1-phase output 或 3-phase input/1-phase output不适用就填空字符串",
"inputPowerFactor": "机架式UPS/在线式高频UPS专属输入侧Power Factor/功率因数,如 ≥0.99@100% load不适用就填空字符串",
"transferTimeAcToBattery": "机架式UPS/在线式高频UPS专属Transfer Time - AC Mode to Battery Mode/转换时间(市电到电池),如 0ms不适用就填空字符串",
"currentCrestRatio": "机架式UPS/在线式高频UPS专属Current Crest Ratio/峰值电流比,如 3:1不适用就填空字符串",
"harmonicDistortion": "机架式UPS/在线式高频UPS专属Harmonic Distortion/谐波失真,如 ≤3% THD (Linear Load), ≤5% THD (Non-linear Load);不适用就填空字符串",
"efficiencyAcMode": "机架式UPS/在线式高频UPS专属Efficiency - AC Mode/效率(市电模式),如 88%;不适用就填空字符串",
"efficiencyBatteryMode": "机架式UPS/在线式高频UPS专属Efficiency - Battery Mode/效率(电池模式),如 83%;不适用就填空字符串",
"chargingVoltage": "机架式UPS/在线式高频UPS专属Charging Voltage/充电电压,如 27.4VDC±1%;如果涉及【型号(L)拆分规则】,要按标准机型/长延时机型分别取Standard Model或Long-run Model那部分的数据不适用就填空字符串",
"optionalSnmp": "机架式UPS/在线式高频UPS专属Optional SNMP/可选SNMP如 Power management from SNMP manager and web browser不适用就填空字符串",
"outputPowerFactor": "在线式高频UPS/太阳能混网逆变器专属Output Power Factor/输出功率因数,如 0.9 或 1不适用就填空字符串",
"parallelUnits": "在线式高频UPS专属Number of Parallel Units/可并联台数,如 Not supported或具体可并联数量不适用就填空字符串",
"overload": "在线式高频UPS专属Overload/过载保护,如 105%-125% 6-25s; >150% 200ms不适用就填空字符串",
"alarmInfo": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Alarm/警告提示,把电池模式/低电量/过载/故障这几种蜂鸣提示规律都列出来(一行一条,用\\n分隔如 Battery mode: Sounding every 10 seconds\\nLow battery: Sounding every second\\nOverload: Sounding every 0.5 seconds\\nFault: Continuously sounding不适用就填空字符串",
"interfacePort": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Interface/控制管理接口说明,如 USB/RS232 port(optional), Support windows xp/vista, windows 7/8/11 and MAC或 Smart RS-232/USB, Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC不适用就填空字符串",
"humidity": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS/UPS配套锂电池系统/太阳能混网逆变器专属Humidity/湿度(或相对湿度),如 0-90% RH@0-40°C(Non-condensing) 或 5%~95%(无凝露);不适用就填空字符串",
"noiseLevel": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS/太阳能混网逆变器专属Noise Level/噪音,如 Less than 40dB(1m spacing);不适用就填空字符串",
"phase": "机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Phase/相数,如 1-phase input/1-phase output 或 3-phase input/1-phase output不适用就填空字符串",
"inputPowerFactor": "机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属输入侧Power Factor/功率因数,如 ≥0.99@100% load不适用就填空字符串",
"transferTimeAcToBattery": "机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Transfer Time - AC Mode to Battery Mode/转换时间(市电到电池),如 0ms不适用就填空字符串",
"currentCrestRatio": "机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Current Crest Ratio/峰值电流比,如 3:1不适用就填空字符串",
"harmonicDistortion": "机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Harmonic Distortion/谐波失真,如 ≤3% THD (Linear Load), ≤5% THD (Non-linear Load);不适用就填空字符串",
"efficiencyAcMode": "机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Efficiency - AC Mode/效率(市电模式),如 88%;不适用就填空字符串",
"efficiencyBatteryMode": "机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Efficiency - Battery Mode/效率(电池模式),如 83%;不适用就填空字符串",
"chargingVoltage": "机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Charging Voltage/充电电压,如 27.4VDC±1%;如果涉及【型号(L)拆分规则】,要按标准机型/长延时机型分别取Standard Model或Long-run Model那部分的数据不适用就填空字符串",
"optionalSnmp": "机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS专属Optional SNMP/可选SNMP如 Power management from SNMP manager and web browser不适用就填空字符串",
"outputPowerFactor": "在线式高频UPS/机架式UPS/工频UPS/高频塔式UPS/模块化UPS/太阳能混网逆变器专属Output Power Factor/输出功率因数,如 0.9 或 1不适用就填空字符串",
"parallelUnits": "在线式高频UPS/机架式UPS/工频UPS/高频塔式UPS/模块化UPS专属Number of Parallel Units/可并联台数,如 Not supported或具体可并联数量不适用就填空字符串",
"overload": "在线式高频UPS/机架式UPS/工频UPS/高频塔式UPS/模块化UPS专属Overload/过载保护,如 105%-125% 6-25s; >150% 200ms不适用就填空字符串",
"moduleType": "UPS配套锂电池系统专属模块类型如 长延时型;不适用就填空字符串",
"moduleCapacity": "UPS配套锂电池系统专属模块额定容量(Ah),如 100不适用就填空字符串",
"cellType": "UPS配套锂电池系统专属电芯类型如 磷酸铁锂电池LFP不适用就填空字符串",
@ -539,7 +539,7 @@ chargeCurrent充电电流、dimensions尺寸、netWeight净重
"cycleLife": "UPS配套锂电池系统专属循环寿命如 5000次@50%DOD不适用就填空字符串",
"commInterface": "UPS配套锂电池系统专属通信接口如 LAN/CAN/RS485/干接点;不适用就填空字符串",
"protectionFunctions": "UPS配套锂电池系统/太阳能混网逆变器专属:保护功能,如 过充、过放、过温、过流、短路等;不适用就填空字符串",
"operatingTemp": "UPS配套锂电池系统/太阳能混网逆变器专属:运行温度,如 0~40℃(推荐20~25℃运行);不适用就填空字符串",
"operatingTemp": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS/UPS配套锂电池系统/太阳能混网逆变器专属:运行温度(或工作温度/工作温度范围),如 0~40℃(推荐20~25℃运行);不适用就填空字符串",
"color": "UPS配套锂电池系统专属颜色如 RAL9004不适用就填空字符串",
"cabinetDimensions": "UPS配套锂电池系统专属电池系统柜尺寸(mm),如 600×850×2000不适用就填空字符串",
"cabinetWeight": "UPS配套锂电池系统专属电池系统柜重量(kg),如 544±108模组配置不适用就填空字符串",
@ -566,9 +566,9 @@ chargeCurrent充电电流、dimensions尺寸、netWeight净重
"efficiencyMppt": "太阳能混网逆变器专属:最大效率(MPPT),如 98%;不适用就填空字符串",
"efficiencyMax": "太阳能混网逆变器专属:最大效率,如 94.5%;不适用就填空字符串",
"efficiencyEurope": "太阳能混网逆变器专属:欧洲效率,如 97.5%;不适用就填空字符串",
"storageTemp": "太阳能混网逆变器专属:存储温度,如 -30~65°C不适用就填空字符串",
"storageTemp": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS/UPS配套锂电池系统/太阳能混网逆变器专属:存储温度,如 -30~65°C(不含电池);不适用就填空字符串",
"cooling": "太阳能混网逆变器专属:散热方式,如 Intelligent forced air cooling不适用就填空字符串",
"protectionClass": "太阳能混网逆变器专属:防护等级,如 IP66不适用就填空字符串",
"protectionClass": "离线式UPS/在线互动式UPS/机架式UPS/在线式高频UPS/工频UPS/高频塔式UPS/模块化UPS/UPS配套锂电池系统/太阳能混网逆变器专属:防护等级(或IP等级),如 IP66 或 IP20;不适用就填空字符串",
"topology": "太阳能混网逆变器专属:拓扑结构,如 HF isolation(Battery side);不适用就填空字符串",
"safetyStandard": "太阳能混网逆变器专属:安规/EMC标准把原文列出来的标准编号都抄下来如 NB/T32004-2018, IEC62109, IEC61000不适用就填空字符串",
"gridStandard": "太阳能混网逆变器专属:并网标准,如 IEC61727, EN50549-1, VDE-4105不适用就填空字符串",